Which radius each supplier makes, how short a flange can be, and how close two bends may sit.
INNER RADIUS / 90° TOOLING
Use the radius the press brake makes
247TailorSteel lists the inner radius its tools produce at 90°, and Sophia® overrides the radius you draw with these values. Xometry asks for Ri ≥ t in ductile metals and ≥ 1.5·t in harder ones. PCBWay warns against assuming an R0 bend.
t (mm)
Steel
Stainless
Aluminium
High-strength
0.8
1.39
1.56
–
–
1
1.40
1.58
1.27
–
1.25
1.42
1.57
–
–
1.5
1.65
1.90
1.47
–
2
1.88
2.22
1.67
–
2.5
2.41
2.94
2.11
–
3
2.75
3.75
2.50
–
4
3.02
4.48
3.30
–
5
3.62
7.82
4.07
–
6
4.62
11.91
5.34
–
8
8.00
11.64
8.12
8.00
10*
8.00
15.00
18.89
8.23
12*
7.83
–
–
7.02
Inner radius in mm at 90° (247TailorSteel). * Full-length bends are not possible at 10 and 12 mm. Stainless above 4 mm moves to a much wider die, so its radius doubles.
Chart 1 · inner radius vs t247TS, 90°
MINIMUM LEG / V-DIE
Give the die something to hold
In air bending the sheet must bridge the V-groove and rest on the shoulder until the bend is done. That sets a minimum leg s, measured to the outside of the flange. Xometry and PCBWay use about 4·t; 247TailorSteel publishes the real table.
View B · air bendingNTS · EM
Chart 2 · minimum leg vs t90° bends
t (mm)
Groove w (mm)
Steel & Al
Stainless
S355 / Corten
0.8
8
5.70
5.70
–
1
8
5.90
5.90
–
1.25
8
6.10
6.10
–
1.5
10
7.50
7.60
8.70
2
12
9.10
9.20
11.50
2.5
16
12.00
12.10
–
3
16 / 20 SS
12.40
15.12
16.80
4
24
17.70
17.90
21.70
5
30 / 40 SS
22.60
29.20
28.70
6
40 / 60 SS
29.60
41.80
29.35
8
60
43.00
43.10
53.20
10*
–
44.00
57.00
55.00
12*
–
56.50
–
56.50
Minimum leg s in mm, 90° bends (247TailorSteel). Sharp bends (< 90° included) need more, e.g. 10 mm at 1 mm steel. One sharp bend makes the sharp table apply to the whole part.
The 4·t rule runs out at 4 mm
What the chart shows
The rule of thumb is close for 1 to 4 mm steel and too optimistic above that. At 6 mm stainless the real minimum is 41.8 mm, about 7·t. For thick or stainless parts, read the table.
Z-BENDS / OFFSET
Offset bends need room for the tool
Two opposite bends close together collide with the punch or die. The limit is the outside-to-outside step x. Pick a material and thickness, then drag x to see whether the second bend still fits.
25 mm
Z-bend, 90°, to scale247TailorSteel table
View F · Z-bendNTS · EM
t (mm)
Steel & Al
Stainless
S355 / Corten
0.8
8.15
8.35
–
1
8.50
8.70
–
1.25
8.95
9.15
–
1.5
10.65
10.95
12.30
2
13.80
14.20
13.40
2.5
18.80
19.45
–
3
20.10
24.75
23.45
4
26.15
27.40
31.80
5
34.65
44.10
40.40
6
42.90
63.20
41.15
8
63.00
66.30
70.40
Minimum x in mm for 90° Z-bends (247TailorSteel). With a sloping web (135° included) the 90° table still applies. Sharp Z-bends (45° included) roughly double this: 34.95 mm at 3 mm steel.
Send us a sheet metal part before it goes out for quotation. We check it against these rules and the supplier you plan to use, and redesign it where it pays: lighter, stiffer or cheaper to make.